RSW 12S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

TECHNICAL INFORMATION

Model Name
RSW 12S
Cold Water Capacity (1hr)
665 lt
Cold Water Capacity (3h)
2000 lt
Cold Water Capacity (6h)
4000 lt
Cold Water Capacity (8hr)
5300 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
21800 watt
Compressor Type
Semi Hermetic
Compressor Displacement
42 m3/h
Compressor Power
12 HP
Compressor Electric Power
8,36 kw/h
Compressor Absorbed Current
14,59 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
0,75
Ethylene Glycol Pump Flow Rate
6 m3/h
Required Condenser Pump Flow
8 m3/h
Water Inlet
2 ınc
Water Outlet
2 ınc
Noise (3 meters)
~78 dBA
Pump Power
380V/1,8A
Dimensions (WxLxh)
1200x550x1150 mm.
Evaporation Temperature
2C / -10C ℃
Weight
520 kg
Energy
380V/50Hz/3Ph



RSW 25S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

TECHNICAL INFORMATION

Model Name
RSW 25S
Cold Water Capacity (1hr)
1665 lt
Cold Water Capacity (3h)
5000 lt
Cold Water Capacity (6h)
10000 lt
Cold Water Capacity (8hr)
13000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
43000 watt
Compressor Type
Semi Hermetic
Compressor Displacement
75 m3/h
Compressor Power
25 HP
Compressor Electric Power
15,86 kw/h
Compressor Absorbed Current
30,7 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Shell and Tube
Ethylene Glycol Pump Flow Rate
11,7 m3/h
Required Condenser Pump Flow
15 m3/h
Water Inlet
2 inch
Water Outlet
2 inch
Noise (3 meters)
~78 dBA
Dimensions (WxLxh)
800x1800x1600 mm.
Evaporation Temperature
2C / -10C ℃
Weight
800 kg
Energy
380V/50Hz/3Ph



RSW 2x35S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 2x35S
Cold Water Capacity (1hr)
5000 lt
Cold Water Capacity (3h)
15000 lt
Cold Water Capacity (6h)
30000 lt
Cold Water Capacity (24hr)
120000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
122.880 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
206 m3/h
Compressor Power
2×35 HP
Compressor Electric Power
49,20 kw/h
Compressor Absorbed Current
84,09 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
2,2 Kw / 3 Hp
Ethylene Glycol Pump Flow Rate
35 m3/h
Required Condenser Pump Flow
50 m3/h
Water Inlet
2 Inch
Water Outlet
2 Inch
Noise (3 meters)
~78 dBA
Evaporation Temperature
2C / -10C ℃
Energy
380V/50Hz/3Ph



RSW 2x50S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 2x50S
Cold Water Capacity (1hr)
7000 lt
Cold Water Capacity (3h)
21000 lt
Cold Water Capacity (6h)
42000 lt
Cold Water Capacity (24hr)
168000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
186.800 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
308,8 m3/h
Compressor Power
2×50 HP
Compressor Electric Power
67,4 kw/h
Compressor Absorbed Current
125 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
2,2 Kw / 3 Hp
Ethylene Glycol Pump Flow Rate
40 m3/h
Required Condenser Pump Flow
65 m3/h
Water Inlet
2 Inch
Water Outlet
2 Inch
Noise (3 meters)
~78 dBA
Dimensions (WxLxh)
1450x2500x1850 mm.
Evaporation Temperature
2C / -10C ℃
Energy
380V/50Hz/3Ph



RSW 2x75S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 2x75S
Cold Water Capacity (1hr)
10000 lt
Cold Water Capacity (3h)
30000 lt
Cold Water Capacity (6h)
60000 lt
Cold Water Capacity (24hr)
240000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
272.800 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
456 m3/h
Compressor Power
2×75 HP
Compressor Electric Power
97,6 kw/h
Compressor Absorbed Current
181,56 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
4 Kw / 5,5 Hp
Ethylene Glycol Pump Flow Rate
52 m3/h
Required Condenser Pump Flow
78 m3/h
Water Inlet
3 Inch
Water Outlet
3 Inch
Noise (3 meters)
~78 dBA
Evaporation Temperature
2C / -10C ℃
Weight
3920 kg
Energy
380V/50Hz/3Ph



RSW 35S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 35S
Cold Water Capacity (1hr)
2500 lt
Cold Water Capacity (3h)
7500 lt
Cold Water Capacity (6h)
15000 lt
Cold Water Capacity (24hr)
60000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
65750 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
106 m3/h
Compressor Power
35 HP
Compressor Electric Power
22,65 kw/h
Compressor Absorbed Current
39,05 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
1,5 Kw / 2 Hp
Ethylene Glycol Pump Flow Rate
12 m3/h
Required Condenser Pump Flow
65 m3/h
Water Inlet
1 1/2 Inch
Water Outlet
1 1/2 Inch
Noise (3 meters)
~78 dBA
Dimensions (WxLxh)
1750x700x1350 mm.
Evaporation Temperature
2C / -10C ℃
Energy
380V/50Hz/3Ph



RSW 3x70S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 3x70S
Cold Water Capacity (1hr)
15000 lt
Cold Water Capacity (3h)
45000 lt
Cold Water Capacity (6h)
90000 lt
Cold Water Capacity (24hr)
360000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
317.107 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
618 m3/h
Compressor Power
3×70 HP
Compressor Electric Power
131,73 kw/h
Compressor Absorbed Current
249,3 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
7,5 Kw / 10 Hp
Ethylene Glycol Pump Flow Rate
65 m3/h
Required Condenser Pump Flow
90 m3/h
Water Inlet
4 Inch
Water Outlet
4 Inch
Noise (3 meters)
~78 dBA
Evaporation Temperature
2C / -10C ℃
Energy
380V/50Hz/3Ph



RSW 40S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 40S
Cold Water Capacity (1hr)
3000 lt
Cold Water Capacity (3h)
9000 lt
Cold Water Capacity (6h)
18000 lt
Cold Water Capacity (8hr)
24000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
96.600 watt
Compressor Type
Semi Hermetic
Compressor Displacement
129,1 m3/h
Compressor Power
40 HP
Compressor Electric Power
28 kw/h
Compressor Absorbed Current
47,9 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Shell and Tube
Condenser – Evaporator Pump Power
4 Hp
Condenser – Evaporator Pump Type
Complete Stainless Steel Centrifugal Pump (AISI316)
Pump Evaporator Water Flow
20 m3/h
Water Pump Electrical Power
4 Kw
Water Inlet
2,5
Water Outlet
Drain 2,5
Noise (3 meters)
~78 dBA
Pump Power
380V/5,2A
Dimensions (WxLxh)
1000x2500x1600 mm.
Evaporation Temperature
2C / -10C ℃
Weight
950 kg
Energy
380V/50Hz/3Ph



RSW 4x75S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 4x75S
Cold Water Capacity (1hr)
20000 lt
Cold Water Capacity (3h)
60000 lt
Cold Water Capacity (6h)
120000 lt
Cold Water Capacity (24hr)
480000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
545.600 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
912 m3/h
Compressor Power
4×75 HP
Compressor Electric Power
195,2 kw/h
Compressor Absorbed Current
363,12 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
11 Kw / 15 Hp
Ethylene Glycol Pump Flow Rate
100 m3/h
Required Condenser Pump Flow
125 m3/h
Water Inlet
4 Inch
Water Outlet
4 Inch
Noise (3 meters)
~78 dBA
Evaporation Temperature
2C / -10C ℃
Energy
380V/50Hz/3Ph