RSW 12S

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

TECHNICAL INFORMATION

Model Name
RSW 12S
Cold Water Capacity (1hr)
665 lt
Cold Water Capacity (3h)
2000 lt
Cold Water Capacity (6h)
4000 lt
Cold Water Capacity (8hr)
5300 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
21800 watt
Compressor Type
Semi Hermetic
Compressor Displacement
42 m3/h
Compressor Power
12 HP
Compressor Electric Power
8,36 kw/h
Compressor Absorbed Current
14,59 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
0,75
Ethylene Glycol Pump Flow Rate
6 m3/h
Required Condenser Pump Flow
8 m3/h
Water Inlet
2 ınc
Water Outlet
2 ınc
Noise (3 meters)
~78 dBA
Pump Power
380V/1,8A
Dimensions (WxLxh)
1200x550x1150 mm.
Evaporation Temperature
2C / -10C ℃
Weight
520 kg
Energy
380V/50Hz/3Ph