Description

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 2x75S
Cold Water Capacity (1hr)
10000 lt
Cold Water Capacity (3h)
30000 lt
Cold Water Capacity (6h)
60000 lt
Cold Water Capacity (24hr)
240000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
272.800 watt
Compressor Type
Semi Hermetic Piston
Compressor Displacement
456 m3/h
Compressor Power
2×75 HP
Compressor Electric Power
97,6 kw/h
Compressor Absorbed Current
181,56 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Titanium Plate
Ethylene Glycol Pump
4 Kw / 5,5 Hp
Ethylene Glycol Pump Flow Rate
52 m3/h
Required Condenser Pump Flow
78 m3/h
Water Inlet
3 Inch
Water Outlet
3 Inch
Noise (3 meters)
~78 dBA
Evaporation Temperature
2C / -10C ℃
Weight
3920 kg
Energy
380V/50Hz/3Ph