Description

In an RSW system, seawater is recirculated by pumps through the tanks and the chilling system. Before entering the tanks, the seawater is chilled by the refrigeration equipment. The seawater is distributed evenly over the complete bottom cross-section of the tanks through a set of perforated plates or similar distribution devices. The chilled seawater passes upwards through the tank and layers of fish, thus keeping the fish semi-floating and simultaneously cooling it. The water returns through suction screens in the top of the thanks to the chilling unit of the system and, subsequently, the circulation process is repeated.

 

TECHNICAL INFORMATION

Model Name
RSW 40S
Cold Water Capacity (1hr)
3000 lt
Cold Water Capacity (3h)
9000 lt
Cold Water Capacity (6h)
18000 lt
Cold Water Capacity (8hr)
24000 lt
Water Outlet Temperature
0 / +2 ℃
Cooling Capacity
96.600 watt
Compressor Type
Semi Hermetic
Compressor Displacement
129,1 m3/h
Compressor Power
40 HP
Compressor Electric Power
28 kw/h
Compressor Absorbed Current
47,9 Amp
Condenser Type
Sea Water Cooling
Evaporator Type
Shell and Tube
Condenser – Evaporator Pump Power
4 Hp
Condenser – Evaporator Pump Type
Complete Stainless Steel Centrifugal Pump (AISI316)
Pump Evaporator Water Flow
20 m3/h
Water Pump Electrical Power
4 Kw
Water Inlet
2,5
Water Outlet
Drain 2,5
Noise (3 meters)
~78 dBA
Pump Power
380V/5,2A
Dimensions (WxLxh)
1000x2500x1600 mm.
Evaporation Temperature
2C / -10C ℃
Weight
950 kg
Energy
380V/50Hz/3Ph